436550
NOTE: In some connection boxes the connector bridges are placed between contacts 4 and 5,
and in the others they are stored at a designated place within the box. These boxes have the
connection screws already in open position so they need not be unscrewed. During the tightening
procedure you will hear a faint “click”, meaning that the tightening screw should be fastened tightly
all the way.
Following cables may be used for connection:
- rubber connecting cables type H05 RR-F 4X1,5 with yellow-green protection conductor;
- PVC insulated connection cables type H05 VV-F 4x1,5 with yellow-green protection conductor or
- any other suitable cable of equal or better properties.
Power supply may be connected by the quali ed technician only.
Connecting sockets are available when you open the connecting
box cover.
WARNING!
Before repairing or servicing, disconnect the power supply.
According to the mains voltage the appliance should be
connected in line with the displayed diagram. Protective
conductor (PE) should be connected to the socket marked
EARTH
.
Connecting cable should be inserted through the clamp device to
prevent eventual pullout.
Upon completed power connection switch all hotplates for about
3 minutes to check they function properly.